Innopak Pre-Split

Updated: October 21, 2024

Product Description

Innopak Pre-Split is a perchlorate-free, continuous, detonator-sensitive emulsion that is crimped every 400 mm (16 in) and can be cut to a desired length.
img-1

Application

Innopak Pre-Split is designed for perimeter control for both surface and underground applications. Its water-resistant characteristics make it suitable for use in small wet holes.

Features

Packaging: Offered in a wide variety of lengths and diameters and packaged in Valeron® film for enhanced durability during loading.

Product Specifications

Nominal density: 1.20 g/m³.

Velocity of Detonation (VOD):  7000 m/s (23,000 ft/s) and is dependent on the VOD of the external detonating cord trace.

RWS and RBS calculated with ANFO density 0.80 g/cc and effective energy 2.260 kJ/kg.

Relative effective energy (%)¹

Product

Relative weight strength

Relative bulk strength

Nominal bulk density (g/cm³)

Gas
volume (L/kg)

Innopak Pre-split

118

178

1.20

893

Guidelines For Use

Innopak products should be kept at temperatures between –15 °C (5 °F) and 55 °C (131 °F) prior to initiation.

Shelf life: 12 months from date of manufacturing stored at temperatures conditions between –20 °C (–4 °F) and 40 °C (104 °F).

First aid: Refer to Safety Data Sheet for first-aid information.

Safety: All explosives are classified as dangerous goods and may cause damage to property, personal harm, or death, if not used correctly.

Priming and Initiation

Innopak Pre-Split is compatible with most non-electric and electronic detonator systems and are reliably initiated with detonators assembled with high strength detonators (No. 8 strength or greater base charge).

Innopak Pre-Split may also be reliably initiated by a 10 g/m (50 gr/ft) detonating cord.

Innopak Pre-Split is externally traced with 10 g/m (50 gr/ft) detonating cord to ensure complete explosive column detonation.

Do not attempt to initiate Innopak Pre-Split with No. 6 strength fuse caps.

Blasthole Charge Length Hole Diameter Density Relationships

Maximum hole depth depends on product selection, hole diameter, product densities, and the presence of water.

Please contact a BME Technical Representative for additional guidance.

Ground Temperature

This product may be used in ground temperatures from to a maximum of 65 °C (150°F) . If the application requires use outside this temperature range please contact a BME Technical Representative for additional guidance.

Reactive Ground

This product is not formulated for use in reactive ground. Reactive ground is typically characterised by the presence of sulphide mineralization. If the application requires use in known reactive ground, or in untested sulphide bearing ground, please contact a BME Technical Representative for additional guidance.

Handling

All explosives must be transported and stored in accordance with local, state and federal regulations.

Product Risk Profile
All explosives are classified as dangerous goods and may cause damage to property, personal harm, or death, if not used correctly. Risk of explosion by shock, friction, fire, or other ignition sources. Classified as hazardous substance, dangerous goods with mass-explosion hazard. Stable under normal storage conditions.

Temperatures above 65°C (150°F) can be hazardous.

Never load a borehole containing hot or burning material.

Never attempt to fight explosives fires.

Never force explosive materials into a borehole.

Refer to Safety Data Sheet for First-Aid information.

Storage

Innopak products should be kept at temperatures between –15°C (5°F) and 55°C (131°F) prior to initiation.

Shelf life is 12 months from date of manufacturing and when stored at temperature conditions between –20°C (–4°F) and 40°C (104°F).

Packaging

Innopak Pre-Split is offered in a wide variety of lengths and diameters and packaged in Valeron® film for enhanced durability during loading.

Case dimensions (L × W × H):
Case Size
445 mm × 343 mm × 216 mm (17-1/2 in × 13-1/2 in × 8-1/2 in).
Nominal Gross Case Weight: 22.7 kg (50 lb).

Nominal stick diameter (mm) Nominal weight (kg/m) Nominal length/case (m) Detonating cord (g/m)
22 0.51 43 10
24 0.61 43 10
32 0.91 24 10
40 1.41 16 10
50 2.46 9 10
Nominal stick diameter (in) Nominal weight (lb/ft) Nominal length/case (ft) Detonating cord (gr/ft)
7/8 0.34 140 50
1 0.41 116 50
1-1/4 0.61 79 50
1-1/2 0.95 51 50
2 1.65 29 50

UN Classification for Transport and Storage

Class 1.1D, UN 0241, EXPLOSIVE, BLASTING, Type E.

Safe Use

  • Never fight explosive fires.
  • Refer to Safety Data Sheet (SDS) for first aid information.
  • All explosives must be transported and stored in accordance to relevant regulations.
  • All explosives are classified as dangerous goods and may cause damage to property, personal harm, or death, if not used correctly.
  • Always keep products away from sources of heat, sparks, flame or hot surfaces and avoid mixing with combustibles or incompatible materials.

 

In case of emergencies, click here to contact our team for assistance.

Disclaimer

All rights reserved. To the maximum extent permitted by law.

Omnia disclaims all liability whatsoever, whether arising in contract, delict (including negligence) or otherwise in relation to the use of any products/solutions or services and all implied warranties, terms and conditions relating to the products/solutions or services (whether implied by statue, common law or otherwise), including (without limitation) any warranty, term or condition as to accuracy, completeness, satisfactory quality, performance, fitness for purpose or any special purpose, non-infringement, information accuracy, as between Omnia and you, are hereby excluded. Omnia specifically disclaims liability and will not be responsible for, any liability or damages, howsoever arising, resulting from the use or reliance upon the information in this document.

You assume sole responsibility for results obtained from the use of the products/solutions or services, and for conclusions drawn from such use.

We continuously update our technical data sheets to reflect the most current and accurate information based on the latest available data. As such, the information provided is subject to revision. We recommend regularly checking for updates to ensure you are accessing the most up-to-date technical details.

Browse:
Innopak Pre-Split

Innopak Pre-Split

img-2
https://bme.co.za/tds/innopak-pre-split
Table of Contents
    Add a header to begin generating the table of contents