Viperdet Trunkline non-electric detonators are used to make connections with Viperdet non-electric products.
Viperdet Trunkline non-electric detonators are used in surface and underground mines, quarries, and construction blasting.
Viperdet Trunkline non-electric detonators must not be used in flammable environments such as methane or coal dust.
Viperdet Trunkline non-electric detonators are safe against extraneous electric currents except lightning.
Detonator strength: No. 3 Detonator.
Shock tube: Triple extruded polyethylene exterior over surlyn inner.
Shell: Aluminium.
Shock tube strength: Resistant to abrasion and cutting under normal handling conditions.
Nominal VOD of shock tube: 2000 m/s.
Connector: Color-coded to identify respective delay timings.
Viperdet Trunkline can be used to sequentially delay and initiate Viperdet MS Downlines.
Maximum number of shock tubes inserted into a Viperdet Trunkline connector is six (6).
Never insert detonating cord into a Viperdet Trunkline connector.
To prevent a snap, slap, and shoot incident (unexpected detonation) never pull or stretch non-electric shock tube to the point of breaking.
Delay time (ms) | Connector colour |
---|---|
17 | Yellow |
25 | Red |
42 | White |
67 | Black |
Storage Conditions
Minimum storage temperature (- 45 °C) and maximum storage temperature (+65 °C).
The product should be stored in its original packaging.
Shelf Life
Viperdet MS Downline shelf life is 36 months when stored in original packaging, under dry conditions and moderate temperature, and in a ventilated and approved magazine.
Disposal
Disposal of expired non-electric detonators and its packaging should conducted of by authorized personnel and/or companies.
Units are placed in plastic inner packaging that is heat-sealed and packed in boxes.
Additional lengths are available on request.
Length (m) |
Units/box |
---|---|
4.2 | 260 |
6 | 250 |
Proper shipping name
Detonator assemblies, non-electric.
Class
1.
Division
1.1 B (UN 0360).
1.4 B (UN 0361).
1.4 B (UN 0500).
In case of emergencies, click here to contact our team for assistance.
Omnia disclaims all liability whatsoever, whether arising in contract, delict (including negligence) or otherwise in relation to the use of any products/solutions or services and all implied warranties, terms and conditions relating to the products/solutions or services (whether implied by statue, common law or otherwise), including (without limitation) any warranty, term or condition as to accuracy, completeness, satisfactory quality, performance, fitness for purpose or any special purpose, non-infringement, information accuracy, as between Omnia and you, are hereby excluded. Omnia specifically disclaims liability and will not be responsible for, any liability or damages, howsoever arising, resulting from the use or reliance upon the information in this document.
You assume sole responsibility for results obtained from the use of the products/solutions or services, and for conclusions drawn from such use.
We continuously update our technical data sheets to reflect the most current and accurate information based on the latest available data. As such, the information provided is subject to revision. We recommend regularly checking for updates to ensure you are accessing the most up-to-date technical details.