AXXIS Titanium Logger

Updated: October 28, 2024

Product Description

The AXXIS Titanium electronic initiation system is the newest generation of AXXIS technology. The system incorporates numerous handling, performance, and safety improvements built upon the highly successful AXXIS GII system. The AXXIS Titanium electronic initiation system is comprised of four components:
  1. Electronic Delay Detonator (EDD).
  2. Logger.
  3. Blasting Box.
  4. Blastmap blast design software.
img-1

Application

The AXXIS Titanium electronic initiation system is designed for use in most general and specialized mining, quarrying, and construction blasting applications on the surface or underground.

The AXXIS Titanium electronic initiation system passes ARP 1717-1: The South African National Standard for the design and approval of EDD initiation systems for mining and civil applications.

Product Specifications

Logging Device AXXIS logger with AXXIS CAP
Operating System Android 8.1
Screen Size 635 mm (5 inches)
Resolution 1280 x 720 pixels
User Interface Colour Touch Screen
  Functions Buttons
  Stylus Enabled
Battery Lithum-ion
Battery Capacity 10.8 V
  3200 mAh
  35 Whr
POD Maximum Output 9 volts
  50 mA
Standby Hours 35 hours
Operating Hours 10 hours
Logger Mass 0.845 kg
Maximum Detonators per Logger 500 detonators per file
  3000 detonators per shared logger
Maximum Detonators per Blast 20 000 Detonators
Logger Functions Log Detonator UIDs
  Program Detonator Firing times
  Test 1 to 500 Detonators
Detonator Communication Via attached CAP
  Read functionality
  Program Functionality
  Test Functionality
Blasting Box Communication Bluetooth or Wired
  QR Code Authentication
Testing Functions Line Current Consumption
  Programmed / Not Programmed
  Detonator Voltage
  Harness Line Test for Missing Detonators
  Harness Line Test for Intruder Detonator
Resistance to Electrostatic Discharge Electrostatic Discharge Immunity Test (+/- 8 kV contact, +/- 15 kV air)
  Electrical Fast Transient / Burst Immunity (+/- 2 kV)
Operating Temperature -30°C and +60°C
Storage Temperature -40°C and +70°C

Guidelines For Use

AXXIS Titanium Loggers may only be programmed, tested, and fired with AXXIS Titanium Electronic Delay Detonators and AXXIS Titanium Blasting Boxes. Do not attempt to program, test, or fire AXXIS Titanium Loggers with other blasting equipment. Never mix electronic delay detonators and/or components from different manufacturers.

AXXIS Titanium Loggers and Blasting Boxes need to be calibrated and serviced by BME qualified personnel or providers every 2 years.

Always use AXXIS Titanium harness wire to tie-in blasts. Do not substitute similar looking harness wire as the performance specifications may not be the same.

Although BME AXXIS Titanium cables are engineered and constructed for challenging work environments, care should still be exercised when loading and stemming to avoid cutting or damaging downlines.

System Usage

AXXIS Titanium Loggers are robust, hand-held devices for the logging and testing of AXXIS Titanium Electronic Detonators. These mobile devices are manufactured by Trimble and have an AXXIS developed POD that docks onto the device.

The POD contains the detonator communication circuit and this enables the logging and programming of AXXIS Titanium Electronic Detonators. The AXXIS Titanium Logger can read and write to the detonator’s non-volatile memory, test a single detonator, test multiple detonators and transfer the logged blast files to the AXXIS Titanium Blasting Box.

AXXIS Titanium Loggers are easy and convenient to handle. They operate on the Android operating system which facilitates the upload of history files, current logging activity, reporting applications and web pages.

In order to operate AXXIS Titanium Blasting Boxes (in Blaster Box mode) at blast firing time, one AXXIS Titanium Logger is configured and designated as the Key Logger. The Key Logger generates a one-time pin to configure the AXXIS Titanium Blasting Boxes (in Blaster Box mode). As a security measure, any AXXIS Titanium Blasting Boxes (in Blaster Box mode) that has not been configured for a blast and bound through the one-time pin on the Key Logger will not function for that blast. At the safe firing point, the Key Logger and the one-time pin is also required to arm the AXXIS Titanium Blasting Box (in Controller Box mode). Upon blast completion, all AXXIS Titanium Loggers and Blasting Boxes return to a neutral un-configured state.

AXXIS EDD technology has a proven track record of delivering mega blasts with thousands of detonators.

Water, Dust and Drop Shock Resistance

AXXIS Titanium EDDs Loggers are robust electronic instruments that are engineered to be water and dust resistant (IEC 60529 IP65 and IP68) and drop shock resistant (IEC 60069-2-32: 1975).

Do not submerge AXXIS Titanium EDD Loggers in water.

Handling

AXXIS Titanium Loggers are robust electronic instruments that need to be used, charged, and stored with care.

Operating Temperature

The AXXIS Titanium Logger may be operated in temperatures from -30°C to a maximum of +60°C. If the application requires use outside of this temperature range please contact a BME Technical Representative for additional guidance.

Storage

The AXXIS Titanium Logger may be stored in temperatures from -40°C to a maximum of +70°C. Please consult with a BME Technical Representative for site specific guidance.

Safe Use

  • Never fight explosive fires.
  • Refer to Safety Data Sheet (SDS) for first aid information.
  • All explosives must be transported and stored in accordance to relevant regulations.
  • All explosives are classified as dangerous goods and may cause damage to property, personal harm, or death, if not used correctly.
  • Always keep products away from sources of heat, sparks, flame or hot surfaces and avoid mixing with combustibles or incompatible materials.

 

In case of emergencies, click here to contact our team for assistance.

Disclaimer

All rights reserved. To the maximum extent permitted by law.

Omnia disclaims all liability whatsoever, whether arising in contract, delict (including negligence) or otherwise in relation to the use of any products/solutions or services and all implied warranties, terms and conditions relating to the products/solutions or services (whether implied by statue, common law or otherwise), including (without limitation) any warranty, term or condition as to accuracy, completeness, satisfactory quality, performance, fitness for purpose or any special purpose, non-infringement, information accuracy, as between Omnia and you, are hereby excluded. Omnia specifically disclaims liability and will not be responsible for, any liability or damages, howsoever arising, resulting from the use or reliance upon the information in this document.

You assume sole responsibility for results obtained from the use of the products/solutions or services, and for conclusions drawn from such use.

We continuously update our technical data sheets to reflect the most current and accurate information based on the latest available data. As such, the information provided is subject to revision. We recommend regularly checking for updates to ensure you are accessing the most up-to-date technical details.

Browse:
AXXIS Titanium Logger

AXXIS Titanium Logger

img-2
https://bme.co.za/tds/axxis-titanium-logger
Table of Contents
    Add a header to begin generating the table of contents