AXXIS Silver Blasting Box

Updated: October 28, 2024

Product Description

The AXXIS Silver electronic initiation system is the newest generation of AXXIS technology. The system incorporates numerous handling, performance, and safety improvements built upon the highly successful AXXIS GII system. AXXIS Silver is a cost effective solution for users wanting to upgrade from the limitations and results of non-electric initiation to the flexibility and added blast performance realized by electronic initiation.
 
The AXXIS Silver electronic initiation system is comprised of four components:

  1. Electronic Delay Detonator (EDD).
  2. Logger.
  3. Blasting Box.
  4. Blastmap blast design software.

Application

The AXXIS Silver electronic initiation system is designed for use in most general and specialized mining, quarrying, and construction blasting applications on the surface or underground. The AXXIS Silver electronic initiation system passes ARP 1717-1: The South African National Standard for the design and approval of EDD initiation systems for mining and civil applications.

Blaster Box Link Set Cable AXXIS Short Range Antenna

AXXIS Long Range ET Plate Antenna

Product Specifications

Blasting Box Housing Hard silver plastic
User Interface Colour LCD with variable intensity and contrast setting
Screen Resolution 2000 x 1500 pixels
Battery 24-volt rechargeable Lithium-ion
Battery Capacity 6000 mAh
Battery life dependent on the number of detonators in each blast
Batteries are not user replaceable
Blasting Box Mass 2.1 kg
Maximum Detonators per Logger 500 detonators per file
Maximum Detonators per Blasting Box in Blaster Box mode 800 Detonators
Maximum Blaster Boxes per Controller Box 2 Blaster Boxes
Maximum Detonators per Blast 1600 Detonators
Controls 2 rotary switches
Spring loading on the full-right position to fire a blast in Controller Box mode
Communication Ports Ports for antenna, charging, USB, harness wire and link cables
QR Code Authentication
Wireless Communication Wireless communication range between Blasting Boxes = 1000 m to 5000 m line of sight
Modem Frequency 158 MHz or 433 MHz or 915 MHz
Resistance to Electrostatic Discharge Electrostatic Discharge Immunity Test (+/- 8kV contact , +/- 15 kV air)
Electrical Fast Transient/Burst Immunity (+/- 2 kV)
Operating Temperature -30°C and +60°C
Storage Temperature -40°C and +70°C

Guidelines For Use

AXXIS Silver Blasting Boxes may only be programmed, tested, and fired with AXXIS Silver Loggers and AXXIS Silver EDDs. Do not attempt to program, test, or fire Silver Blasting Boxes with other blasting equipment. Never mix electronic delay detonators and/or components from different manufacturers.

AXXIS Silver Loggers and Blasting Boxes need to be calibrated and serviced by BME qualified personnel or providers every 2 years.

Always use AXXIS harness wire to tie-in blasts. Do not substitute similar looking harness wire as the performance specifications may not be the same.

Although BME AXXIS Silver cables are engineered and constructed for challenging work environments, care should still be exercised when loading and stemming to avoid cutting or damaging downlines.

System Usage

Blasting Boxes
All AXXIS Silver Blasting Boxes are the same. Each AXXIS Silver Blasting Box is configurable to a Blaster Box or a Controller Box to accomplish its required function. Blasting Box operation is simple, with double rotary switches for switching a box on, placing it in standby mode, and opening communications channels to fire the blast. Wireless communications are achieved through three selectable open-band frequency channels. Other frequency channels can be configured based on the country requirements.

Blaster Box

AXXIS Silver Blasting Boxes configured as Blaster Boxes are placed at each blast site and connected to the surface wire harness. No power is supplied to the detonators until system arming from the Controller Box at blasting time.

Each Blaster Box can fire up to 800 detonators. In large single blasts where more than one Blaster Box is needed, the Blaster Boxes are hard-wired together using AXXIS link sets. Up to 2 Blasting Boxes may be linked together for a total combined firing capability of 1600 detonators in a single blast.

Controller Box
Only one Blasting Box may be configured as a Controller Box per blast. The Controller Box requires the presence of a Key Logger to authorise arming and firing of the system. On arming of the system with the Controller Box, each Blaster Box then powers up its detonators, and testing routines automatically start and continue until firing time. Detonators respond by exception, allowing a quick testing time and immediate warnings to the operator through the color screen on the Controller Box and the Key Logger.

Combiner Box

A Blasting Box may be configured as a Combiner Box. The Combo Box configuration is useful in quarry and construction blasting where the harness line-in line from the blast can be directly connected (hard-wired) into the Combiner Box at the safe firing point.

The Blasting-Controller Combiner Box requires the presence of a Key Logger to authorise arming and firing of the system. On arming of the system with the Blaster-Controller Combiner Box, the detonators are powered up, and testing routines automatically start and continue until firing time. Detonators respond by exception, allowing a quick testing time and immediate warnings to the operator through the color screen on the Blaser-Controller Combiner Box and the Key Logger.

Antennas
Two types of AXXIS Silver system specific antennas are available. The short-range antenna can be used for line-of-sight distances up to 1200 m. Depending on frequency allocation, the long- range ET Plate antenna can be used for line-of-sight distances between 1500 m and 5000 m.

Water, Dust and Drop Shock Resistance

Silver Blasting Boxes are robust electronic instruments that are engineered to be water and dust resistant (IEC 60529 IP65 and IP68) and drop shock resistant (IEC 60069-2-32: 1975). AXXIS Silver EDD Loggers are not waterproof – Do not submerge Silver Blasting Boxes in water.

Handling

Silver Blasting Boxes are robust electronic instruments that are engineered to be water and dust resistant (IEC 60529 IP65 and IP68) and drop shock resistant (IEC 60069-2-32: 1975). AXXIS Silver EDD Loggers are not waterproof – Do not submerge Silver Blasting Boxes in water.

Storage

The Silver Blasting Boxes may be operated in temperatures from -30°C to a maximum of +60°C. If the application requires use outside of this temperature range please contact a BME Technical Representative for additional guidance.

Safe Use

  • Never fight explosive fires.
  • Refer to Safety Data Sheet (SDS) for first aid information.
  • All explosives must be transported and stored in accordance to relevant regulations.
  • All explosives are classified as dangerous goods and may cause damage to property, personal harm, or death, if not used correctly.
  • Always keep products away from sources of heat, sparks, flame or hot surfaces and avoid mixing with combustibles or incompatible materials.

 

In case of emergencies, click here to contact our team for assistance.

Disclaimer

All rights reserved. To the maximum extent permitted by law.

Omnia disclaims all liability whatsoever, whether arising in contract, delict (including negligence) or otherwise in relation to the use of any products/solutions or services and all implied warranties, terms and conditions relating to the products/solutions or services (whether implied by statue, common law or otherwise), including (without limitation) any warranty, term or condition as to accuracy, completeness, satisfactory quality, performance, fitness for purpose or any special purpose, non-infringement, information accuracy, as between Omnia and you, are hereby excluded. Omnia specifically disclaims liability and will not be responsible for, any liability or damages, howsoever arising, resulting from the use or reliance upon the information in this document.

You assume sole responsibility for results obtained from the use of the products/solutions or services, and for conclusions drawn from such use.

We continuously update our technical data sheets to reflect the most current and accurate information based on the latest available data. As such, the information provided is subject to revision. We recommend regularly checking for updates to ensure you are accessing the most up-to-date technical details.

Browse:
AXXIS Silver Blasting Box

AXXIS Silver Blasting Box

https://bme.co.za/tds/axxis-silver-blasting-box