Viperdet LP

Updated: October 28, 2024

Product Description

Viperdet LP is a non-electric long-period delay detonator. Viperdet LP assemblies are precise and reliable. Units consist of a specific length of yellow shock tube with a high-strength delay detonator crimped to the one end and a seal at the other end. A detonating cord connector clip is attached to the sealed end.
img-1

Application

Viperdet LP non-electric detonators are designed for use in underground mining and tunnelling.

Viperdet LP non-electric detonators must not be used in flammable environments such as methane or coal dust.

Viperdet non-electric detonators are safe against extraneous electric currents except lightning.

Features

Detonator strength: No. 8 detonator with a double crimp.

Shock tube: Yellow, with three layers coiled in a 'Figure 80' for ease of deployment and the avoidance of tangles. The shock tube is resistant to abrasion and designed to elongate to avoid tensile strength damage under normal use conditions.

J-Hook: J-hook to ease connection to detonating cord (5 g/m minimum core load).

Label tag: Water resistant. Laser printing provides clear and smudge resistant timing and product information.

Guidelines For Use

Priming and Initiation

Viperdet LP non-electric detonators can be initiated by a single strand of detonating cord with a minimum core load of 5 g/m.

Viperdet LP non-electric detonators can be used to prime the full range of BME's detonator sensitive explosive products.

To prevent a snap, slap, and shoot incident (unexpected detonation) never pull or stretch non-electric shock tube to the point of breaking.

Ground Temperature

This product may be used in ground temperatures up to a maximum of 65 °C (150 °F). If the application requires use outside of this temperature range please contact a BME Technical Representative for additional guidance.

Delay Times

Delay Time (ms)
1 100
2 200
3 300
4 400
5 500
6 600
7 700
8 800
9 900
10 1000
12 1200
14 1400
16 1600
18 1800
20 2000
25 2500
30 3000
35 3500
40 4000
45 4500
50 5000
55 5500
60 6000
70 7000
80 8000
90 9000

Sleep Time

The recommended maximum sleep time is 21 days. If the application requires longer in-hole sleep time, please consult with a BME Technical Representative for guidance.

Handling

All explosives must be transported and stored in accordance with relevant local, state and federal regulations.

Product Risk Profile
All explosives are classified as dangerous goods and may cause damage to property, personal harm, or death, if not used correctly.

Severe detonation hazard when exposed to heat.
Detonation may occur from impact, friction, or excessive heating.
Never attempt to fight explosives fires.

First Aid: Refer to Safety Data Sheet for first-aid information.

Storage

Viperdet LP shelf life is 36 months when stored in the original packaging, under dry conditions at moderate temperatures, and in a well ventilated and approved magazine.

Packaging

Standard lengths below. Fastest available delivery time.
Additional lengths upon request.
Unit packaging is in coils.
All specifications may vary slightly from the stated nominal.

1.1B Classification

Length (m) Length (ft) Units/
case
Gross weight (kg) Gross weight (lb) Net weight (kg) Net weight (lb)
4.8 16 240 12 26 10 22
6 20 180 10 22 8 18
7.8 26 150 10 22 8 18

UN Classification for Transport and Storage

Class
1.1B, UN 0360, DETONATOR ASSEMBLIES, NON-ELECTRIC.
1.4B, UN 0361, DETONATOR ASSEMBLIES, NON-ELECTRIC.
1.4S, UN 0500, DETONATOR ASSEMBLIES, NON-ELECTRIC.

Safe Use

  • Never fight explosive fires.
  • Refer to Safety Data Sheet (SDS) for first aid information.
  • All explosives must be transported and stored in accordance to relevant regulations.
  • All explosives are classified as dangerous goods and may cause damage to property, personal harm, or death, if not used correctly.
  • Always keep products away from sources of heat, sparks, flame or hot surfaces and avoid mixing with combustibles or incompatible materials.

 

In case of emergencies, click here to contact our team for assistance.

Disclaimer

All rights reserved. To the maximum extent permitted by law.

Omnia disclaims all liability whatsoever, whether arising in contract, delict (including negligence) or otherwise in relation to the use of any products/solutions or services and all implied warranties, terms and conditions relating to the products/solutions or services (whether implied by statue, common law or otherwise), including (without limitation) any warranty, term or condition as to accuracy, completeness, satisfactory quality, performance, fitness for purpose or any special purpose, non-infringement, information accuracy, as between Omnia and you, are hereby excluded. Omnia specifically disclaims liability and will not be responsible for, any liability or damages, howsoever arising, resulting from the use or reliance upon the information in this document.

You assume sole responsibility for results obtained from the use of the products/solutions or services, and for conclusions drawn from such use.

We continuously update our technical data sheets to reflect the most current and accurate information based on the latest available data. As such, the information provided is subject to revision. We recommend regularly checking for updates to ensure you are accessing the most up-to-date technical details.

Browse:
Viperdet LP

Viperdet LP

img-2
https://bme.co.za/tds/viperdet-lp
Table of Contents
    Add a header to begin generating the table of contents