AXXIS Titanium Electronic Delay Detonator

Electronic Delay Detonator

April 12, 2021

Product Description

The AXXIS Titanium electronic initiation system is the newest generation of AXXIS technology. The AXXIS Titanium electronic initiation system incorporates numerous handling, performance, and safety improvements built upon the highly successful AXXIS GII system.

The AXXIS Titanium electronic initiation system is comprised of four components:

25 AXXIS Titanium Electronic Delay Detonator LR 1

Application

The AXXIS Titanium electronic initiation system is designed for use in most general and specialized mining, quarrying, and construction blasting applications on the surface or underground. The AXXIS Titanium electronic initiation system passes ARP 1717-1: The South African National Standard for the design and approval of EDD initiation systems for mining and civil applications.

Primary Benefits

Blasting Boxes

AXXIS Titanium EDDs safety includes dual capacitors that split the system into two. The logic capacitor is used to communicate and test the detonator and does not have enough storing energy to fire the fuse head. The firing capacitor is only used for firing. The logic capacitor has an internal shunt that when commanded switches gates from logic mode to firing mode. Only in firing mode is the firing capacitor then calibrated and charged for blasting.

The AXXIS Titanium system utilises dual voltage for detonator logging and testing at low voltage. Error testing is reported by exemption thus considerably speeding up the testing and blasting process at the firing point. It takes less then two minutes to finalize a blast for firing regardless of the number of detonators.

AXXIS Titanium Electronic Delay Detonator performance features include a non-volatile detonator memory. Detonators are programmed and tested during logging by writing the desired firing times and log sequence number into each detonators memory. Once detonators are programmed during logging there is no need to re-programme on powering up again. The detonator history is recorded permanently to the detonator memory making it ideal for track and trace.

AXXIS Titanium EDDs have engineered cables that are highly resistant to damage and cut offs due to a balanced combination of tensile, elongation, and abrasion resistance. This results in a very low rate of misfire occurrence even under the most challenging hole loading conditions.

AXXIS EDD technology has a proven track record of delivering mega blasts with thousands of detonators.

Specifications

Colum 1Column 2
Delay Time Range0 to 35 seconds (35 000 ms) in 1 ms increments
Delay Accuracy (COV)At ambient temperature up to 8 seconds < 1ms
Above 8 seconds, better than 0.02%
Maximum Detonators per Logger500 detonators per file
3000 detonators per logger
Maximum Detonators per Blasting Box1000 detonators
Maximum Detonators per Blast Controller20 000 detonators
Detonator ShellAluminium magnesium or copper alloy
Detonator DimensionsNominal outer diameter = 7.5 mm
Nominal length = 88.9 mm
Fits standard boosters
Detonator Charge1.0 g
South Africa # 8 strength
CableHDPE outer insulation and PVC inner insulation over copper or copper cladded steel cores
Operating Temperature-40°C and +80°C
Hydrostatic Resistance14 bars for 7 days
Dynamic Shock Resistance80 MPa

Packaging

Column 1Column 2Column 3Column 5Column 6
Detonator Cable Length1.1 B Units per Case1.1 B Max Weight per Case (kg)1.4 S Units per Case1.4 S Max Weight per Case (kg)
5 m14415.258011.30
6 m12614.958011.92
8 m12017.805613.75
10 m10418.205614.35
12 m8817.855214.61
15 m8020.205618.52
20 m6420.504016.35
25 m4818.503215.51
30 m4018.402815.70

Custom lengths on request.

Guidelines for Use

AXXIS Titanium electronic delay detonators may only be programmed, tested, and fired with AXXIS Titanium Loggers and AXXIS Titanium Blasting Boxes. Do not attempt to program, test, or fire AXXIS Titanium EDDs with other blasting equipment. Never mix electronic delay detonators and/or components from different manufacturers.
 
AXXIS Titanium Loggers and Blasting Boxes need to be calibrated and serviced by BME qualified personnel or providers every 2 years.
 
Always use AXXIS Titanium harness wire to tie-in blasts. Do not substitute similar looking harness wire as the performance specifications may not be the same.
 
Although BME AXXIS Titanium cables are engineered and constructed for challenging work environments, care should still be exercised when loading and stemming to avoid cutting or damaging downlines.

Ground Temperature

This product may be used in ground temperatures from -40°C to a maximum of +80°C. If the application requires use outside of this temperature range please contact a BME Technical Representative for additional guidance.

Reactive Ground

Reactive ground is typically characterised by the presence of sulphide mineralization. If the application requires use in known reactive ground, or in untested sulphide bearing ground, please contact a BME Technical Representative for additional guidance.

Sleep-Time

The recommended maximum sleep time is 45 days. Sleep time is dependent on factors such as hole depth, explosive column type, and ground water conditions. If the application requires longer in-hole sleep time, please consult with a BME Technical Representative for guidance.

Storage

The storage life for AXXIS Titanium EDDs is 60 months under good storage conditions. Please consult with a BME Technical Representative for site specific storage life guidance.

Safe Use

  • Never fight explosive fires.
  • Refer to Safety Data Sheet (SDS) for first aid.
  • All explosives must be transported and stored in accordance to relevant regulations.

UN Classification for Transport and Storage

Product Classification for Transport and Storage

  • Authorised Name: AXXIS TITANIUM

  • Correct Shipping Name: DETONATORS, ELECTRONIC programmable for blasting

  • Classification: 1.1B manufactured in South Africa, UN Number: 0511

  • Classification: 1.4S manufactured in South Africa, UN Number: 0513

Disclaimer

All rights reserved. To the maximum extent permitted by law: Omnia disclaims all liability whatsoever, whether arising in contract, delict (including negligence) or otherwise in relation to the use of the TDS and all implied warranties, terms and conditions relating to the TDS (whether implied by statue, common law or otherwise), including (without limitation) any warranty, term or condition as to accuracy, completeness, satisfactory quality, performance, fitness for purpose or any special purpose, non-infringement, information accuracy, as between Omnia and you, are hereby excluded. Omnia specifically disclaims liability and will not be responsible for, any liability or damages, howsoever arising, resulting from the use or reliance upon the information in this document.

You assume sole responsibility for results obtained from the use of the TDS, and for conclusions drawn from such use.

Use of the product by a user is at the user’s risk.

ColourAxxis-Titanium-with-Circle512-px-1.png
ColourManufactured-by-BME-copy-2512-px.png
ColourAxxis-Titanium512-px-1.png
ColourManufactured-by-BME-copy-2512-px.png

© Omnia Group (Pty) Ltd

Contents

BME Head Office
South Africa

Omnia Holdings, Building H:
Monte Circle Business Park
178 Montecasino Boulevard,
Fourways, Sandton, 2191

Subscription Form

© An OMNIA Group Company. All rights reserved.

Web Design by Teracore