Download BME's Blasting Guide App >

AXXIS CEBS UG Logger

Updated: April 8, 2025

Product Description

AXXIS Loggers are robust, hand-held devices that allow logging and testing of detonators. The mobile device is handheld and has an AXXIS developed CAP, which docks onto the device. The CAP contains the Detonator Communication Circuit. This makes it possible the log and program the detonators. It can read or write to the detonators non-volatile memory, test a single detonator, test multiple detonators and transfer the logged blast files to the blaster.
AXXIS CEBS Logger

Technical Properties

Type Robust Handheld Device.
Operating system Android 11 Enterprise.
Colour Grey and Black.
Detonator Communication
  • Via Attached CAP.
  • Communication 1-500 Detonators Connected.
  • Read Functionality.
  • Program Functionality.
  • Test Functionality.
Blaster Communication
  • Bluetooth, Wired, QR Scan.
  • NFC Authentication.
User Interface
  • Colour Touch Screen.
  • Function Buttons.
  • Rain Mode.
Screen Size
  • 6 Inch.
  • 1080x1920.
Battery Lithiom-ion.
Battery Capacity
  • 3.8 V.
  • 8000 mAh.
  • 30.4 Whr.
POD Maximum Output 9 volts, 70 mA.
Logger Mass 610 g.
Logger Function
  • Scanning UID’s.
  • Programming Firing Times.
  • Programming to Detonator NVM.
  • Centralise Programming 1-500 Detonators Connected.
  • Testing 1-500 Detonators Connected.
Testing Functions
  • Detonator Program Status.
  • Detonator Program Details.
  • Detonator Temperature.
  • Line Current Consumption.
  • Leakage Test.
  • Line Test for Connected.
  • Line Test for Missing.
  • Line Test for Intruders.
Detonators Per Log Line 500.
Detonators Per Log File 20 000.
Intruder Detection 500 Connected.

 

Environmental:

Conform to Specification SANS 1717-1: The South African 

National Standard for: Design and 

Approval of EDD Initiation Systems: 

Mining and Civil Blasting.

Resistance to ESD
  • Electrostatic Discharge Immunity Test (±8kV contact, ±15kV air).
  • Electrical Fast Transient / Burst Immunity (±2kV).
Calibration Intervals 2 Years.
Water/Dust Ingress Water/Dust Ingress.
Drop Shock Protection IEC 60068-2-32:1975: 122cm
Temperature
  • Operation: -20 °C to +55 °C.
  • Storage: -40 °C to +70 °C.

Guidelines For Use

In order to configure the blaster at fire time, a Key Logger is required.

This operates with a one-time pin. The pin is generated and managed by the software. As a security measure, any blaster that has not been configured for the blast and bound through the one-time pin on the Key Logger, will not function for that blast.

The Key Logger and the one-time pin are required at the Blast Controller for the system to be armed.

Upon Blast completion, all loggers and blasters return to a neutral un-configured state.

Files are stored in memory and can be archived by the User.

Water, Dust and Drop Shock Resistance

IEC 60068-2-32:1975: 122cm

Operating Temperature

-20 °C to +55 °C

Storage

Storage Temperature:
-40 °C to +70 °C

Safe Use

  • Never fight explosive fires.
  • Refer to Safety Data Sheet (SDS) for first aid information.
  • All explosives must be transported and stored in accordance to relevant regulations.
  • All explosives are classified as dangerous goods and may cause damage to property, personal harm, or death, if not used correctly.
  • Always keep products away from sources of heat, sparks, flame or hot surfaces and avoid mixing with combustibles or incompatible materials.

 

In case of emergencies, click here to contact our team for assistance.

Disclaimer

All rights reserved. To the maximum extent permitted by law.

Omnia disclaims all liability whatsoever, whether arising in contract, delict (including negligence) or otherwise in relation to the use of any products/solutions or services and all implied warranties, terms and conditions relating to the products/solutions or services (whether implied by statue, common law or otherwise), including (without limitation) any warranty, term or condition as to accuracy, completeness, satisfactory quality, performance, fitness for purpose or any special purpose, non-infringement, information accuracy, as between Omnia and you, are hereby excluded. Omnia specifically disclaims liability and will not be responsible for, any liability or damages, howsoever arising, resulting from the use or reliance upon the information in this document.

You assume sole responsibility for results obtained from the use of the products/solutions or services, and for conclusions drawn from such use.

We continuously update our technical data sheets to reflect the most current and accurate information based on the latest available data. As such, the information provided is subject to revision. We recommend regularly checking for updates to ensure you are accessing the most up-to-date technical details.

Browse:
AXXIS CEBS UG Logger

AXXIS CEBS UG Logger

https://bme.co.za/tds/axxis-cebs-ug-logger